Heat Bank Thermal Store System  
Xcel unit for connection to remote F+E  
Single Heat Exchanger (30 ltr/min)  
40mm Foam Insulation  
GX-Plan primary controls  
Underfloor Primaries  
All fitted controls are wired  
Thermostatic Blending Valve 22mm  
Backup Immersion Heater  


2   Plate Heat Exchanger
3   Heat Exchanger Pump
4   Flow Switch
5   Thermostatic Blending Valve, Mixcall III
6   Manual Air Vent
8   Vent
11  Y-Pattern Strainer (supplied loose)
13  Cold Feed / Expansion
14  Immersion Heater 3kW Incaloy with Stat
16  Cold Mains In, 22mm
17  Hot Mains Out, 22mm
18  Drain Cock
19  Flow From Boiler
20  Return to Boiler
27  Boiler Pump UPS 15/50
38  Cylinder Immersion Thermostat
41  Primary Blending Valve
42  Wiring Centre

 

Unit ID

XC-130-1649-1XC-150-1649-1XC-180-1649-1XC-210-1649-1XC-250-1649-1XC-300-1649-1

Capacity

130150180210250300

Base Diameter

450450450450450500

Overall Diameter

530530530530530580

Height

119013301510172019801900

Contents:
1. Introduction
2. General Requirements
3. Mains Water Supply
4. Connections:
5. Wiring
6. Filling
7. Commissioning
8. Fault Finding
9. Servicing
10. Spares
11. User Instructions